INVT Inverter Goodrive10 Series Manual

The INVT Goodrive10 Series Inverter is designed for various applications, providing high performance and reliability. This manual covers key features, installation procedures, operational guidelines, and troubleshooting tips to ensure optimal use of the inverter.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operating the Inverter 8. Maintenance 9. Safety Information 10. Troubleshooting

Features at a Glance

The Goodrive10 Series offers advanced features including vector control, built-in PID control, and multiple communication protocols. It is suitable for various motor types and applications.

FeatureDescription
Vector ControlProvides precise control of motor speed and torque.
Built-in PID ControlAllows for automatic control of process variables.
Multiple Communication ProtocolsSupports Modbus, CANopen, and other protocols for integration.
Compact DesignSpace-saving design suitable for various installations.
Overload ProtectionProtects the inverter and motor from overload conditions.

Installation

Ensure proper installation for optimal performance. Follow the steps below:

  1. Mount the inverter securely in a well-ventilated area.
  2. Connect the input power supply according to the wiring diagram.
  3. Connect the output to the motor ensuring correct phase alignment.
  4. Ground the inverter properly to prevent electrical hazards.

WARNING! Ensure all power is disconnected before installation to avoid electric shock.

First-Time Setup

After installation, power on the inverter and follow these steps:

  1. Set the motor parameters using the keypad or software.
  2. Configure the control mode (V/F or vector control).
  3. Test the inverter with no load before connecting the motor.
  4. Adjust settings as necessary for optimal performance.

CAUTION! Verify all connections before powering on the inverter.

Specifications

Controls and Settings

The inverter features an intuitive keypad for easy operation. Key controls include:

Keypad: Start, Stop, Up, Down, and Menu buttons for navigation.

Display: Shows operational status, fault codes, and parameter settings.

Connecting Devices

Follow these steps to connect external devices:

  1. Ensure the inverter is powered off before making connections.
  2. Connect the motor to the inverter output terminals.
  3. Connect any external control devices as per the wiring diagram.
  4. Power on the inverter and test the connections.

Tip: Always refer to the wiring diagram for correct connections.

Operating the Inverter

To operate the inverter:

  1. Press the Start button to initiate operation.
  2. Monitor the display for operational status and any fault indications.
  3. Adjust speed and torque settings as required during operation.
  4. Press Stop to halt operation safely.

WARNING! Do not operate the inverter beyond its rated capacity.

Maintenance

Regular maintenance is essential for longevity:

Safety Information

Follow these safety guidelines:

Troubleshooting

SymptomPossible CauseCorrective Action
Inverter does not startNo power supplyCheck input power connections.
Overload alarmExcessive loadReduce load and reset the inverter.
Fault code displayedInternal errorRefer to the fault code list in the manual.
Motor not runningIncorrect wiringVerify motor connections and phase alignment.

Reset: Use the reset function in the menu if available.